Lifting magnet ¨C Model B
|
|
|
|
ATTENTION: Never move the lever to the "ON" position unless the magnet is placed on an iron or steel object.
|
|
|
|
|
Lever in the "ON" position. Note the pin safety lock is engaged.
|
Lever in the "OFF" position.
|
|
|
Maximum Rated Load Plate Steel
|
Model
|
Material
|
Maximum Rated Load
|
Minimum Thickness
|
LM-150B
|
plate steel
|
150kg
|
20mm
|
LM-300B
|
plate steel
|
300kg
|
25mm
|
LM-600B
|
plate steel
|
600kg
|
30mm
|
LM-1200B
|
plate steel
|
1200kg
|
45mm
|
LM-2400B
|
plate steel
|
2400kg
|
55mm
|
|
|
Maximum Rated Load Plate Steel
|
Model
|
Material
|
Maximum Rated Load
|
Diameter Range
|
Minimum Length
|
LM-150B
|
round steel
|
80kg
|
50-200
|
20mm
|
LM-300B
|
round steel
|
150kg
|
25-300
|
25mm
|
LM-600B
|
round steel
|
300kg
|
100-500
|
30mm
|
LM-1200B
|
round steel
|
600kg
|
150-700
|
45mm
|
LM-2400B
|
round steel
|
1200kg
|
150-800
|
55mm
|
|
|
|
Dimensions(mm)
|
Model
|
A
|
B
|
C
|
D
|
E
|
F
|
G
|
H
|
Wt.
|
LM-150B
|
105
|
85
|
120
|
125
|
60
|
70
|
40
|
30
|
3kg
|
LM-300B
|
180
|
155
|
155
|
185
|
90
|
95
|
50
|
40
|
9kg
|
LM-600B
|
250
|
225
|
210
|
260
|
115
|
120
|
75
|
50
|
23kg
|
LM-1200B
|
280
|
240
|
287
|
370
|
165
|
170
|
95
|
87
|
50kg
|
LM-2400B
|
420
|
380
|
350
|
500
|
215
|
215
|
105
|
125
|
120kg
|
|
|
|
|
|
|
Lifting power depends upon carbon content of stock, stock thickness, and surface finish.
|
Lifting Power BY MATERIALS
|
|
0%
|
50%
|
100%
|
|
M1
|
Low Carbon
|
100%
|
M2
|
Moderate Carbon
|
85%
|
M3
|
High Carbon
|
75%
|
M4
|
Cast Iron
|
70%
|
|
Effect of Surface Finish
|
|
0%
|
50%
|
100%
|
150%
|
|
F1
|
Ground Surface
|
125%
|
F2
|
Rough Machined
|
100%
|
F3
|
Foundry Finish
|
90%
|
F4
|
Rough Cast
|
65%
|
|
|
|
Percent of Lifting Power (by thickness of material)
|
Thickness
|
Depth
|
LM-150B
|
LM-300B
|
LM-600B
|
LM-1200B
|
LM-2400B
|
T1
|
2.36 in
|
100%
|
100%
|
100%
|
100%
|
100%
|
T2
|
2.16 in
|
100%
|
100%
|
100%
|
100%
|
100%
|
T3
|
1.97 in
|
100%
|
100%
|
100%
|
100%
|
95%
|
T4
|
1.77 in
|
100%
|
100%
|
100%
|
100%
|
90%
|
T5
|
1.57 in
|
100%
|
100%
|
100%
|
100%
|
85%
|
T6
|
1.38 in
|
100%
|
100%
|
100%
|
90%
|
75%
|
T7
|
1.18 in
|
100%
|
100%
|
100%
|
80%
|
65%
|
T8
|
0.98 in
|
100%
|
100%
|
90%
|
70%
|
55%
|
T9
|
0.79 in
|
100%
|
90%
|
75%
|
60%
|
45%
|
T10
|
0.59 in
|
100%
|
70%
|
60%
|
50%
|
35%
|
T11
|
0.39 in
|
70%
|
50%
|
45%
|
35%
|
25%
|
T12
|
0.20 in
|
40%
|
30%
|
25%
|
20%
|
15%
|
|
Calculation Example: LM-600B, rated lifting power is 600 kg. The formula for calculating range of lifting capacity is: T x F x M x G x Capacity.
T = Thickness
F = Surface Finish
M = Material
G = Air Gap
ELM-600 Example: T8, F1, M2 and G
90% x 125% x 85% x 100% x 600 = 573.75kg
|